The excellent insulating value and heat capacity of masonry and concrete make this system a good choice for schools and commercial buildings.
Backup: Reinforced 8" thick concrete wall. #5 reinforcement at 12 inches o.c. each direction, 2 mats of steel9-gauge triangular ties in dovetail slots embedded in concrete. Install the dovetail slots vertically @ 24" o.c. Install ties in the slots @ 16" o.c.Veneer: Cored modular brick 4" x 2-13" x 8" (nom.).Insulation: 2 inch extruded polystyrene rigid insulation in 3 inch drainage cavity.flashing: Base flashing and weeps.Mortar: Type N, Portland cement/lime, plain gray.Joints: Concave tooled.
4 hours
STC 62.7
STC=(weight of wall)0.223x21.5
122 lb/sq. ft.
R-value: 11.89 with 2” expanded polystyrene rigid insulation (See note)
Calculation:
R-value: 13.89 with 2” extruded polystyrene rigid insulation (See note)
Note: The type of rigid insulation you install affects the wall’s insulating capacity (the R-value). Polyisocyanurate insulation gives you 8.0 R per inch (12.0 R for 1.5" or R16 for 2"). Expanded polystyrene insulation is worth 4.0 R per inch (6.0 R for 1.5" or 8 R for 2"). Extruded polystyrene yields 5.0 R per inch (7.5 R for 1.5" or 10 R for 2"). Use either thicker insulation or more expensive polyisocyanurate to achieve a higher energy rating.
This efficient and economical masonry system allows a single layer of brick to perform as both the structure and the exposed surface of the wall.
This versatile wall system features a durable, low-maintenance masonry façade with a steel structure.
This solid masonry wall features a structural concrete block backup system with a classic, natural stone facade.
This efficient and economical masonry system allows a single layer of concrete block to serve as the structure and the exposed surface of the wall.